Calibration of critical flow nuzzles by volumetric method Cd
dc.creator | Rivera López, Jesús Eduardo | |
dc.creator | Díaz Martínez, Alejandro | |
dc.creator | Tamayo Mesa, Pedro Alejandro | |
dc.creator | Gutiérrez Paredes, Guadalupe Juliana | |
dc.creator | Orozco Durán, Gabriela Esmeralda | |
dc.creator | Arciniega Martínez, José Luis | |
dc.date | 2021-10-01 | |
dc.date.accessioned | 2024-03-01T21:11:18Z | |
dc.date.available | 2024-03-01T21:11:18Z | |
dc.description | the present work, the objective is to improve the measurement of gas flow through the use of critical flow nozzles (Critical Flow Venturi Nozzles), for this, the calibration procedure of two critical flow nozzles with diameters in the throat of 0.022 and 0.088 inches. The procedure developed is based on the recommendations made by the ISO 9300 Standard for the estimation and calculation of the discharge coefficient "Cd" of the critical flow nozzles. The calibration was carried out at the National Metrology Center (CENAM) with the use of national gas flow standards. The standards used or testers are of the type: Piston and Bell, with a measurement range of 0.05 to 50 L / min, and from 50 to 2840 L / min, respectively. The method used to calibrate the nozzles was by direct comparison with the standard. | en-US |
dc.description | En el presente trabajo, se tiene por objetivo mejorar la medición de flujo de gases por medio del uso de toberas de flujo crítico (Critical Flow Venturi Nozzles), para ello, se describe el procedimiento de calibración de dos toberas de flujo crítico con diámetros en la garganta de 0.022 y 0.088 pulgadas. El procedimiento desarrollado tiene como base las recomendaciones que hace la Norma ISO 9300 para la estimación y cálculo del coeficiente de descarga “Cd” de las toberas de flujo crítico. La calibración se realizó en el Centro Nacional de Metrología (CENAM) con el uso de los patrones nacionales de flujo de gas. Los patrones utilizados o probadores son del tipo: Pistón y Campana, con un rango de medición de 0.05 a 50 L/min, y de 50 a 2840 L/min, respectivamente. El método utilizado para la calibración de las toberas fue mediante la comparación directa con el patrón. | es-ES |
dc.format | application/pdf | |
dc.format | text/html | |
dc.format | text/xml | |
dc.identifier | https://recit.uabc.mx/index.php/revista/article/view/139 | |
dc.identifier | 10.37636/recit.v43245255 | |
dc.identifier.uri | https://repositorioinstitucional.uabc.mx/handle/20.500.12930/11218 | |
dc.language | spa | |
dc.publisher | Universidad Autónoma de Baja California | en-US |
dc.relation | https://recit.uabc.mx/index.php/revista/article/view/139/242 | |
dc.relation | https://recit.uabc.mx/index.php/revista/article/view/139/364 | |
dc.relation | https://recit.uabc.mx/index.php/revista/article/view/139/365 | |
dc.rights | Copyright (c) 2021 Jesús Eduardo Rivera López, Alejandro Díaz Martínez, Pedro Alejandro Tamayo Mesa, Guadalupe Juliana Gutiérrez Paredes, Gabriela Esmeralda Orozco Durán, José Luis Arciniega Martínez | en-US |
dc.rights | https://creativecommons.org/licenses/by/4.0 | en-US |
dc.source | REVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 4 No. 3 (2021): July-September; 245-255 | en-US |
dc.source | REVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 4 Núm. 3 (2021): Julio-Septiembre; 245-255 | es-ES |
dc.source | 2594-1925 | |
dc.subject | Flujo crítico | es-ES |
dc.subject | Calibración | es-ES |
dc.subject | Microtobera | es-ES |
dc.subject | Estimación de la incertidumbre | es-ES |
dc.subject | Patrones | es-ES |
dc.subject | Critical flow | en-US |
dc.subject | Calibration | en-US |
dc.subject | Micro nozzle | en-US |
dc.subject | Estimation of uncertainity | en-US |
dc.subject | Standards | en-US |
dc.title | Calibration of critical flow nuzzles by volumetric method Cd | en-US |
dc.title | Calibración de toberas de flujo crítico por método volumétrico Cd | es-ES |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion |