Determination of faults severity in power transformers immersed in mineral insulated oil based exclusively on the DGA and by evaluating the NEI

dc.creatorGutiérrez Chávez, Bethsaida Adriana
dc.creatorMontes de Oca-Ramírez, Georgina
dc.date2021-09-27
dc.date.accessioned2024-03-01T21:10:21Z
dc.date.available2024-03-01T21:10:21Z
dc.descriptionThe power transformer is a major part of an electric system, it is necessary to know their condition in order to solve incipient faults, DGA technique in mineral insulating oil is widely used to diagnose the equipment, however, is not easy to interpret the results because it is hard to know the severity of the detected fault. Recent studies mention a way to evaluate it called “Normalized Energy Intensity” (Jakob & Dukarm, 2015) which incorporates the thermodynamic theory to the decomposition of mineral insulated oil. In this article, the analysis of 24 power transformers operating under different conditions was considered to do a comparative study between Dissolved Gas Analysis and Normalized Energy Intensity interpretation techniques in order to evaluate the severity of the detected faults. The obtained result was a more accurate diagnosis of the transformers before presenting major failures. It was determined that the interpretative technique NEI is more sensitive to DGA, allowing that the quantification of the transformer fault severity to be closer to the insulated mineral oil real condition degradation.en-US
dc.descriptionLos transformadores de potencia son un componente importante de las redes eléctricas, por lo que resulta necesario conocer su estado a fin de dar solución a las fallas incipientes. La técnica Análisis de Gases Disueltos (DGA) es ampliamente utilizada para el diagnóstico de fallas de estos equipos, sin embargo, los resultados no son concluyentes ya que no se conoce con exactitud la severidad de las fallas detectadas. En estudios recientes se reporta una manera de evaluación “Normalized Energy Intensity (NEI)” (Jakob & Dukarm, 2015), la cual incorpora la teoría termodinámica a la degradación del aceite mineral. En este artículo se realiza el análisis de 24 transformadores de potencia que operan bajo distintas condiciones, realizando una evaluación comparativa de las técnicas de interpretación DGA y NEI para evaluar la severidad de las fallas detectadas. El resultado obtenido fue un diagnóstico más certero de los transformadores previo a presentar fallas mayores. Se determinó que la técnica interpretativa NEI es más sensible al DGA, permitiendo que la cuantificación de la severidad de la falla del transformador sea más aproximada al estado real de la degradación de aceite mineral aislante. es-ES
dc.formatapplication/pdf
dc.formattext/html
dc.formattext/xml
dc.identifierhttps://recit.uabc.mx/index.php/revista/article/view/138
dc.identifier10.37636/recit.v43208223
dc.identifier.urihttps://repositorioinstitucional.uabc.mx/handle/20.500.12930/11217
dc.languagespa
dc.publisherUniversidad Autónoma de Baja Californiaen-US
dc.relationhttps://recit.uabc.mx/index.php/revista/article/view/138/288
dc.relationhttps://recit.uabc.mx/index.php/revista/article/view/138/289
dc.relationhttps://recit.uabc.mx/index.php/revista/article/view/138/290
dc.rightsCopyright (c) 2021 Bethsaida Adriana Gutiérrez Chávez, Georgina Montes de Oca-Ramírezen-US
dc.rightshttps://creativecommons.org/licenses/by/4.0en-US
dc.sourceREVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 4 No. 3 (2021): July-September; 208-223en-US
dc.sourceREVISTA DE CIENCIAS TECNOLÓGICAS; Vol. 4 Núm. 3 (2021): Julio-Septiembre; 208-223es-ES
dc.source2594-1925
dc.subjectPower transformeren-US
dc.subjectMineral insulating oilen-US
dc.subjectDissolved gas analysis (DGA)en-US
dc.subjectNormalized energy intensity (NEI)en-US
dc.subjectEnthalpyen-US
dc.subjectTransformador de potenciaes-ES
dc.subjectAceite mineral aislantees-ES
dc.subjectAnálisis de gases disueltos (DGA)es-ES
dc.subjectIntensidad energética normalizada (NEI)es-ES
dc.subjectEntalpíaes-ES
dc.titleDetermination of faults severity in power transformers immersed in mineral insulated oil based exclusively on the DGA and by evaluating the NEIen-US
dc.titleDeterminación de fallas en transformadores de potencia inmersos en aceite mineral aislante basándose exclusivamente en el DGA y mediante la evaluación del NEIes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion